亲子乱高潮1000部,色婷婷五月综合亚洲小说,禁伦H肉高辣网站视频,亚洲成av人影院

粉體行業(yè)在線展覽

產(chǎn)品

產(chǎn)品>

粉體測試設(shè)備>

質(zhì)譜檢測分析儀

>布魯克timsTOF™ Pro捕集離子淌度質(zhì)譜

布魯克timsTOF™ Pro捕集離子淌度質(zhì)譜

直接聯(lián)系

布魯克·道爾頓(Bruker Daltonics)

德國

產(chǎn)品規(guī)格型號(hào)
參考報(bào)價(jià):

面議

關(guān)注度:

1176

產(chǎn)品介紹

the timsTOF™ Pro Mass Spectrometer Enables the Revolutionary PASEF Method for Next-Generation Proteomics

Unique Trapped Ion Mobility Spectrometry (TIMS) Adds New Dimension for Robust, Faster Proteome Analysis with Higher Sensitivity

Overview

  • Powered by PASEF

Mass spectrometry (MS)-based proteomics has become a powerful technology for the identification and quantification of thousands of proteins. However, the coverage of complete proteomes is still very challenging due to the limited speed, sensitivity and resolution of current mass spectrometers.

The timsTOF Pro uses the Parallel Accumulation Serial Fragmentation (PASEF) acquisition method to provide extremely high speed and sensitivity to reach new depths in shotgun proteomics and phosphoproteomics using low sample amounts.

  • Achieve near 100% duty cycle for shotgun proteomics

A near 100% duty cycle for high sensitivity, high speed shotgun proteomics can now be achieved with the dual TIMS technology. The novel design allows for ions to be accumulated in the front section, while ions in the rear section are simultaneously released depending on their ion mobility. This process is called Parallel Accumulation Serial Fragmentation or PASEF.

  • PASEF digs deeper into the proteome

The timsTOF Pro powered by PASEF offers sequencing speed > 100 Hz without losing sensitivity by synchronizing the quadrupole isolation mass window with the elution time of the specific peptide packages from the TIMS funnel.

  • MaxQuant/Perseus and PEAKS Studio enabled data processing

An open-file data format allows researchers to directly work with the raw data and use industry leading software. MaxQuant has been adapted to manage 4D features in the space spanned by retention time, ion mobility, mass, and signal intensity which benefit the identification and quantification of peptides, proteins, and posttranslational modifications. PEAKS Studio combines de novo sequencingwith tradtional databbase searches and is optimized for processing timsTOF raw data.

Technical Details

  • Outstanding hardware performance

The second generation dual TIMS analyzer is optimized for shotgun proteomics needs. Due to its unique geometry ions are released dependent on their mobility from the second section of the TIMS analyzer while the further incoming ions can be accumulated in parallel in the first part of the TIMS analyzer. With the parallel accumulation technology a duty cycle up to 100% can be achieved resulting in no ion loss.

In the timsTOF Pro an advanced segmented quadrupole mass filter is used for high ion transmission and isolation efficiency. The quadrupole mass position is synchronized with the elution times of the specific ions from the TIMS analyzer. Due to its ultra-high mass position switching time (< 1 ms) it enables the best performance for the PASEF method.

  • TIMS

Trapped Ion Mobility Spectrometry (TIMS) is first and foremost a separation technique in gas phase, which resolves sample complexity with an added dimension of separation in addition to HPLC and mass spectrometry, increasing peak capacity and confidence in compound characterization.

  • PASEF

With speed in mind, Bruker experts redesigned MS/MS technology to meet the requirements of shotgun proteomics. Peptide ions are separated using trapped ion mobility spectrometry, eluted (~ 100 ms) and detected in the QTOF, generating the TIMS MS heat map (A). In the PASEF method (B) the same TIMS separation is used with the quadrupole isolating a certain ion species during its elution and immediately shifting to the next precursor. Parent and fragment spectra are aligned by mobility values. With the Parallel Accumulation Serial Fragmentation (PASEF) Technology >100 Hz sequencing speed can be achieved. With the PASEF method the MS/MS spectra quality of the low abundant peptides can be increased by selecting them several times.

產(chǎn)品咨詢

布魯克timsTOF™ Pro捕集離子淌度質(zhì)譜

布魯克·道爾頓(Bruker Daltonics)

請?zhí)顚懩男彰?

請?zhí)顚懩碾娫挘?

請?zhí)顚懩泥]箱:*

請?zhí)顚懩膯挝?公司名稱:*

請?zhí)岢瞿膯栴}:*

您需要的服務(wù):

發(fā)送

中國粉體網(wǎng)保護(hù)您的隱私權(quán):請參閱 我們的保密政策 來了解您數(shù)據(jù)的處理以及您這方面享有的權(quán)利。 您繼續(xù)訪問我們的網(wǎng)站,表明您接受 我們的使用條款

布魯克timsTOF™ Pro捕集離子淌度質(zhì)譜 - 1176
布魯克·道爾頓(Bruker Daltonics) 的其他產(chǎn)品

FLOW

質(zhì)譜檢測分析儀
相關(guān)搜索
關(guān)于我們
聯(lián)系我們
成為參展商

© 2025 版權(quán)所有 - 京ICP證050428號(hào)

主站蜘蛛池模板: 南召县| 深州市| 华宁县| 桂平市| 京山县| 留坝县| 马边| 阿克陶县| 天台县| 武胜县| 田林县| 饶平县| 河源市| 安新县| 乌鲁木齐县| 邛崃市| 邵阳县| 观塘区| 万荣县| 资源县| 海晏县| 东阳市| 枣阳市| 景洪市| 墨脱县| 历史| 通州市| 荆州市| 临武县| 新乡市| 普宁市| 潜江市| 吕梁市| 奉贤区| 常熟市| 运城市| 元谋县| 库伦旗| 哈密市| 吴堡县| 鹤壁市|